![]() |
![]() |
![]() |
![]() |
![]() |
||||
|
||||||||
>> Back to Tools Menu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Geoprobe® implants are unique in their ability to be "Post Run"... they are not carried in the rod during probe driving, but rather inserted down the bore when the appropriate depth has been reached. Once the implant is slid down the bore, it is simply rotated to attach it to the anchor point used during driving. As probe rods are removed from the hole, the implant and associated tubing remain firmly anchored at the bottom. Geoprobe® implants are constructed of double woven stainless steel wire screen. All end fittings are stainless steel as well. Implants are available in 6-in. (152 mm) lengths with the AT86 series, 21-in. (533 mm) lengths with the AT87 series, or 14-in. (356 mm) lengths with the latest AT96 series. The user can also connect multiple 21-in. (533 mm) lengths together using the AT89 series implants. Geoprobe® implants have a pore diameter of 0,0057 inch (0.145 mm). The bottom end of Geoprobe® implants use our standard "PRT" style thread, the same fitting style used with our popular PRT vapor sampling tools. The AT89 implant uses a PRT socket thread at its top end, allowing multiple lengths to be coupled together. Geoprobe® Permanent Implants Advantages...
Geoprobe® Prepacked Sparge Points are an alternative to using implants for air sparging. The sparge points are installed through 2.25- and 2.125 in. probe rod using flexible tubing instead of PVC riser. Each Prepacked Sparge Point includes a compression fitting for connecting 0.625 in. OD tubing. These discrete interval sparge points have been used at many facilities for sparging groundwater to achieve remediation goals for volatile contaminants. Now, with the increase in vapor intrusion investigations, you can also use them for soil gas monitoring applications. They are less expensive to use than typical implants, are available with 0.75 in. PVC and 0.5 in PVC. The stainless screen is 50 mesh (0.011- in. openings), and the slot size is the same as standard Geoprobe® prepacks, 0.010 in. (commonly referred to as ten-slot).
Geoprobe's
stainless steel implants for the 1.25-in. probe rod system. PRT
fitting at the base attaches to Implant Anchor. Top end
fits poly tubing with 0.5-in. OD x 0.375 ID.
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Copyright© 2007 Kejr, Inc. Geoprobe Systems® is a Division of Kejr, Inc. | ||